
Productos importados de Estados Unidos, es probable que los productos electronicos trabajen en 110V y NO en 220V, podria usar un transformador, para mas informacion primero nos puedes preguntar todas las inquietudes que tengas. Fotos referenciales del producto, consulte no mas Depende de precio con proveedores o existencia. There are many different ways that the light path can be modified to improve the contrast and image of the sample from an optical microscope.- El producto se trae a pedido, en un transcurso de 15 a 25 dias, si alguna restriccion de un ente gubernamental o de salud publica cambia o restringe vuelos, los pedidos pueden demorar mas tiempo. However, this is usually a sign that the eye is focusing at a close distance, rather than beyond the subject. Some people may complain of tired eyes or headaches after using an optical microscope. Focusing on the close range of the sample image can lead to tension headaches and tired eyes. The image created by any microscope should be viewed with the eyes focused at infinity, beyond the subject. Changing to the next objective lens and readjusting the focus, condenser and light as needed to view the image clearly.Īfter using an optical microscope, the stage should be lowered so that the microscope slide can easily be removed.Adjusting the focus knob, condenser and light intensity once again to improve the clarity of the image.Moving the microscope slide around to being the part of interest of the sample into the center of the field of view.Changing the condenser and intensity of light to increase the contrast of the image.Viewing the sample through the eyepiece and adjusting the focus knob to bring the image into focus.Adjusting the height of the stage so that it is as close as possible to the objective without contact between the lens and the sample.Placing the microscope slide with the sample to be examined onto the stage and fasten in place.Adjusting the objective lens to the lowest power of resolution.Preparing the microscope slide with the sample to be examined, including a coverslip over the sample.Operating techniquesĪ compound optical microscope, which is the most common type of optical microscope used in scientific research, can be operated as follows: This creates a couplet, which allows the virtual image to focus between the lenses so that the eye is able to focus on the virtual image. Most optical microscopes have a compound lens eyepiece, with one lens at the front and one at the back of the eyepiece tube.



The real image created by the objective lens is further enlarged by the ocular lens so that an individual can view it. This allows the light from the sample to come to a focus approximately 160 mm within the tube of the microscope, creating an enlarged and inverted image of the subject. It is a lens with a short focal length and should, therefore, be held close to the sample that is being examined. The objective lens of an optical microscope is similar to a very strong magnifying glass. The basic principles to operate an optical microscope are relatively simple. Introduction to the Light Microscope Play Principles of operation
